Features

Optical Fiber I&M

The compact, battery-powered and easy-to-use Anritsu MT1000A provides everything needed to install and maintain communication networks in a rugged, field portable package. This lightweight instrument simplifies the daunting task of collecting and interpreting data with an easy-to-use GUI and clear summaries allowing users of any skill level to operate the instrument to its full potential.

The MT1000A is multi-function tester that can be configured with an array of transport testing functions and OTDR modules to ensure you have the tools you need today plus the expandability for future technologies – all of which are field upgradeable.

  • Verify proper fiber installation and fiber loss characteristics are within the specified budget
  • Fiber Visualizer simplifies testing with an easy to read graphical summary of the results
  • Ability to toggle between graphical summary and traditional OTDR trace
  • Specialized testing modes simplify operation
  • High resolution and dynamic range ensure quick and thorough fiber evaluation
  • Intelligent analysis software identifies problem splices, connectors and even macrobends
  • Test multiple wavelengths with a single unit
  • One button PDF report generation
  • Standard power meter and light source
  • Visual fault locator option
  • Verify fiber end face condition (dust, scratches) and cleanliness with optional connector inspection microscope

Mobile Network I&M

  • Mobile Fronthaul and Backhaul - Optical Loss, Reflectance and ORL Measurements
    • Hybrid single mode fiber (1310 nm/1550 nm), multimode fiber (850 nm/1300 nm) models
    • 3 wavelength single mode fiber model (1310nm/1550nm/1625nm)
    • All-in-one OTDR, light source, optical power meter, visible light source (option)
    • Multi-pulse measurement for high-accuracy event detection
    • CPRI/OBSAI measurement with simultaneously installed Multi-rate Module MU100010A/MU100011A
    • Optical connector inspection with IEC 61300-3-35 Pass/Fail
  • Easy-to-Use, Easy-to-Report
    • Graphical summary and Pass/Fail evaluation using Fiber Visualizer function
    • Intuitive touchscreen operation
    • One button, comprehensive PDF report generation

Core and Metro Network Long Range I&M

  • Easily test long fibers 100 km or more
  • Three single mode fiber (1310 nm/1550 nm) models: Standard, Enhanced, High-Performance
  • 3 wavelength single mode fiber (1310nm/1550nm/1625nm) model: High-Performance
  • Automated file naming/file saving and fast data acquisition reduce testing times
  • Construction OTDR mode for cable installation: Automated testing of multiple fibers at multiple wavelengths

FTTx and PON I&M

  • Easily test PON Networks with up to 1×128 count splitters
  • Multi-pulse measurement for high splitter loss measurement and high resolution testing
  • Splitter identification by size with individual Pass/Fail

 

Description

Installing Complex Mobile Networks

The worldwide spread of mobile devices, such as smartphones and tablets using SNS, video streaming, etc., is causing an explosive increase in data traffic volumes. Mobile network base stations are configured using various methods, but the antenna radio section uses an optical fiber to connect the BBU an RRH passing via a general interface called the CPRI/OBSAI. The need for optical fiber fault finding and transport quality tests increases as the Mobile network environment becomes more advanced. Installing the 10G Multirate Module MU100010A/100G Multirate Module MU100011A and OTDR Module MU100020A/21A/22A in the Network Master Pro MT1000A supports all-in-one optical fiber fault finding and transport quality tests.
Using the MU100020A/21A/22A, scratched or dirty connectors at fiber cable connections can be detected as fault locations from the excessive optical reflections to support fault finding and troubleshooting of Mobile optical networks. Additionally, work efficiency is greatly improved using the Fiber Visualizer function supporting Easy-to-Use/Easy-to-Report testing.

OTDR Module Applications

Generally, depending on the optical fiber measurement environment, OTDR measurements require multiple settings such as distance range, pulse width, measurement time, etc., making work difficult for technicians who do not generally use an OTDR. When performing Pass/Fail evaluation of an optical circuit for a report, a simple intuitive GUI is key to improving work efficiency.
The MU100020A/MU100021A/MU100022A emphasizes easy-to-understand operability using three application measurement modes: OTDR Measurement, FTTA Measurement, and OLTS Measurement.

otdr  Standard OTDR Measurements

The OTDR measurement results are displayed as a trace showing the optical fiber length, losses and size of reflections, as well as an easy-to-view summary of the analysis results on the Fiber Visualizer screen.

  • Event icons showing characteristics of each connector, splice, and far end
  • Pass/Fail evaluations based on user-settable threshold values

The user can set any threshold value for each event. If the Pass/Fail evaluation settings prescribed in the engineering manual are set beforehand, the measured optical fiber loss status can be easily distinguished visually at the same time as measurement ends.

ftta  FTTA Measurements

Comparatively short optical fibers of around several hundred meters in length are usually installed at the Mobile fronthaul FTTA. In this type of measurement environment, measurements made by different operators under different conditions commonly have inconsistency problems at later data processing.
At FTTA measurement, the optical fiber installation measurement conditions are fixed previously, so measurements are always made under the same conditions whoever is performing measurement.
Like the OTDR measurement function, each measurement result can be analyzed at the Trace and Fiber Visualizer screens.

construction  Construction Measurement

The Construction mode measurement greatly simplifies through its innovative wizard. In particular, this is very effective function for user when multi-fibers construction is the task at hand. The ability to auto name and save the traces using a wizard, this allows the ability to adjust naming based on test direction, wavelength and fiber number. This minimizes the required user input especially on large fiber count cables which require testing on multiple wavelengths. Ensures no lost data and minimizes required input from the onsite engineers.

olts  OLTS Measurements

At measurement of the optical Physical layer, the first basic measurement is loss measurement using a light source and power meter. With a built-in light source and power meter as standard, the MU100020A/MU100021A/MU100022A can be used as an optical loss test set (OLTS). In addition, measurement results can be managed at the Loss Table for Pass/Fail evaluation of individual data based on set threshold values.

 

Specifications

OTDR Module MU100020A

OptionsMU100020A-020MU100020A-021MU100020A-022
Wavelength 1310 nm/1550 nm ±25 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 39 dB/37.5 dB 42 dB/41 dB

46 dB/46 dB

25 dB/25 dB (Pulse Width: 100 ns)

Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m

OTDR Module MU100021A

OptionsMU100021A-021
Wavelength 1310 nm/1550 nm ±25 nm 850 nm/1300 nm ±30 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
GI Fiber
62.5 µm/125 µm
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns

850 nm: 
3, 10, 20, 50, 100, 200, 500 ns

1310 nm: 
3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000 ns

Dynamic Range 42 dB/41 dB 29 dB/28 dB
Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m ≤4.0 m/5.0 m

OTDR Module MU100022A

OptionsMU100022A-022
Wavelength 1310 nm/1550 nm/1625 nm ±25 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 46 dB/46 dB/44 dB
25 dB/25 dB/23 dB (Pulse Width: 100 ns)
Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m/4.8 m

 MT1000A Series Product Brochure      Fiber Visualizer Appn Note    MT1000 Product Introduction    G0306B Inspection Scope

Anritsu Logo

MU100020A/21A

* required fields

iFactory Testing Only ( this does not show on the live site! )

this is an export of the data that the Javascript needs to make the choices of (*cable refrence number)

Token
Type: String
1318ec242e9ca65c87e344f5d654434f
Smarty Version
Type: String
Smarty-3.1.13
Product ID
Type: Interger
595
Product URL
Type: String
/test-and-inspection-equipment/595-mu1000a-series-otdr
Product Length
Type: Interger
Product Name
Type: String
MU1000A SERIES OTDR
Product Category
Type: String
test-and-inspection-equipment
Cable Refrence
Type: String
MU100020A/21A

Quick Enquiry

Want this product? Then make a quick enquiry below, it couldn't be simpler
* Required fields.

Features

Optical Fiber I&M

The compact, battery-powered and easy-to-use Anritsu MT1000A provides everything needed to install and maintain communication networks in a rugged, field portable package. This lightweight instrument simplifies the daunting task of collecting and interpreting data with an easy-to-use GUI and clear summaries allowing users of any skill level to operate the instrument to its full potential.

The MT1000A is multi-function tester that can be configured with an array of transport testing functions and OTDR modules to ensure you have the tools you need today plus the expandability for future technologies – all of which are field upgradeable.

  • Verify proper fiber installation and fiber loss characteristics are within the specified budget
  • Fiber Visualizer simplifies testing with an easy to read graphical summary of the results
  • Ability to toggle between graphical summary and traditional OTDR trace
  • Specialized testing modes simplify operation
  • High resolution and dynamic range ensure quick and thorough fiber evaluation
  • Intelligent analysis software identifies problem splices, connectors and even macrobends
  • Test multiple wavelengths with a single unit
  • One button PDF report generation
  • Standard power meter and light source
  • Visual fault locator option
  • Verify fiber end face condition (dust, scratches) and cleanliness with optional connector inspection microscope

Mobile Network I&M

  • Mobile Fronthaul and Backhaul - Optical Loss, Reflectance and ORL Measurements
    • Hybrid single mode fiber (1310 nm/1550 nm), multimode fiber (850 nm/1300 nm) models
    • 3 wavelength single mode fiber model (1310nm/1550nm/1625nm)
    • All-in-one OTDR, light source, optical power meter, visible light source (option)
    • Multi-pulse measurement for high-accuracy event detection
    • CPRI/OBSAI measurement with simultaneously installed Multi-rate Module MU100010A/MU100011A
    • Optical connector inspection with IEC 61300-3-35 Pass/Fail
  • Easy-to-Use, Easy-to-Report
    • Graphical summary and Pass/Fail evaluation using Fiber Visualizer function
    • Intuitive touchscreen operation
    • One button, comprehensive PDF report generation

Core and Metro Network Long Range I&M

  • Easily test long fibers 100 km or more
  • Three single mode fiber (1310 nm/1550 nm) models: Standard, Enhanced, High-Performance
  • 3 wavelength single mode fiber (1310nm/1550nm/1625nm) model: High-Performance
  • Automated file naming/file saving and fast data acquisition reduce testing times
  • Construction OTDR mode for cable installation: Automated testing of multiple fibers at multiple wavelengths

FTTx and PON I&M

  • Easily test PON Networks with up to 1×128 count splitters
  • Multi-pulse measurement for high splitter loss measurement and high resolution testing
  • Splitter identification by size with individual Pass/Fail

 

Description

Installing Complex Mobile Networks

The worldwide spread of mobile devices, such as smartphones and tablets using SNS, video streaming, etc., is causing an explosive increase in data traffic volumes. Mobile network base stations are configured using various methods, but the antenna radio section uses an optical fiber to connect the BBU an RRH passing via a general interface called the CPRI/OBSAI. The need for optical fiber fault finding and transport quality tests increases as the Mobile network environment becomes more advanced. Installing the 10G Multirate Module MU100010A/100G Multirate Module MU100011A and OTDR Module MU100020A/21A/22A in the Network Master Pro MT1000A supports all-in-one optical fiber fault finding and transport quality tests.
Using the MU100020A/21A/22A, scratched or dirty connectors at fiber cable connections can be detected as fault locations from the excessive optical reflections to support fault finding and troubleshooting of Mobile optical networks. Additionally, work efficiency is greatly improved using the Fiber Visualizer function supporting Easy-to-Use/Easy-to-Report testing.

OTDR Module Applications

Generally, depending on the optical fiber measurement environment, OTDR measurements require multiple settings such as distance range, pulse width, measurement time, etc., making work difficult for technicians who do not generally use an OTDR. When performing Pass/Fail evaluation of an optical circuit for a report, a simple intuitive GUI is key to improving work efficiency.
The MU100020A/MU100021A/MU100022A emphasizes easy-to-understand operability using three application measurement modes: OTDR Measurement, FTTA Measurement, and OLTS Measurement.

otdr  Standard OTDR Measurements

The OTDR measurement results are displayed as a trace showing the optical fiber length, losses and size of reflections, as well as an easy-to-view summary of the analysis results on the Fiber Visualizer screen.

  • Event icons showing characteristics of each connector, splice, and far end
  • Pass/Fail evaluations based on user-settable threshold values

The user can set any threshold value for each event. If the Pass/Fail evaluation settings prescribed in the engineering manual are set beforehand, the measured optical fiber loss status can be easily distinguished visually at the same time as measurement ends.

ftta  FTTA Measurements

Comparatively short optical fibers of around several hundred meters in length are usually installed at the Mobile fronthaul FTTA. In this type of measurement environment, measurements made by different operators under different conditions commonly have inconsistency problems at later data processing.
At FTTA measurement, the optical fiber installation measurement conditions are fixed previously, so measurements are always made under the same conditions whoever is performing measurement.
Like the OTDR measurement function, each measurement result can be analyzed at the Trace and Fiber Visualizer screens.

construction  Construction Measurement

The Construction mode measurement greatly simplifies through its innovative wizard. In particular, this is very effective function for user when multi-fibers construction is the task at hand. The ability to auto name and save the traces using a wizard, this allows the ability to adjust naming based on test direction, wavelength and fiber number. This minimizes the required user input especially on large fiber count cables which require testing on multiple wavelengths. Ensures no lost data and minimizes required input from the onsite engineers.

olts  OLTS Measurements

At measurement of the optical Physical layer, the first basic measurement is loss measurement using a light source and power meter. With a built-in light source and power meter as standard, the MU100020A/MU100021A/MU100022A can be used as an optical loss test set (OLTS). In addition, measurement results can be managed at the Loss Table for Pass/Fail evaluation of individual data based on set threshold values.

 

Specifications

OTDR Module MU100020A

OptionsMU100020A-020MU100020A-021MU100020A-022
Wavelength 1310 nm/1550 nm ±25 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 39 dB/37.5 dB 42 dB/41 dB

46 dB/46 dB

25 dB/25 dB (Pulse Width: 100 ns)

Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m

OTDR Module MU100021A

OptionsMU100021A-021
Wavelength 1310 nm/1550 nm ±25 nm 850 nm/1300 nm ±30 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
GI Fiber
62.5 µm/125 µm
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns

850 nm: 
3, 10, 20, 50, 100, 200, 500 ns

1310 nm: 
3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000 ns

Dynamic Range 42 dB/41 dB 29 dB/28 dB
Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m ≤4.0 m/5.0 m

OTDR Module MU100022A

OptionsMU100022A-022
Wavelength 1310 nm/1550 nm/1625 nm ±25 nm
Fiber Type Single Mode Fiber (SMF)
10 µm/125 µm
ITU-T G.652
Pulse Width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 46 dB/46 dB/44 dB
25 dB/25 dB/23 dB (Pulse Width: 100 ns)
Deadzone
(Fresnel)
(IOR = 1.500000)
≤80 cm (typ.)
Deadzone
(Backscatter)
(IOR = 1.500000)
≤3.8 m/4.3 m/4.8 m